This product is a water-based one-component inorganic coating composed of inorganic film formers, inorganic pigments and additives. It can meet Class A fire protection requirements and is the preferred interior wall coating for large apartments and underground parking lots.
Caractéristiques du produit :
*Classe A de résistance au feu, répondant aux exigences de protection contre l'incendie pour les grands bâtiments publics.
*Emulsion inorganique, pigment inorganique, formule professionnelle
*Les coûts sont élevés et les indicateurs de protection de l'environnement sont excellents.
*Alkaline system, moisture-proof and mildew-proof
Champ d'application :
Il peut être largement utilisé dans les grands appartements, les parkings souterrains, etc.
Technical parameters Implementation standards: GB/T9756-2018, GB18582-2008, GB50222-2017, GB8624-2012
Theoretical paint consumption: 6~8 square meters/kg/two coats (calculated based on dry film thickness of 30 microns)
Temps de séchage : 1 heure pour le séchage en surface (à une température ambiante de 23°C et une humidité relative de 50%)
Sécher pendant 2 heures (à une température ambiante de 23°C et une humidité relative de 50%)
Temps de recouvrement : 4 heures (à une température ambiante de 23°C et une humidité relative de 50%
Rapport de contraste : 0,95
Scrub resistance: 6000 times
Shelf life: 24 months from the date of production (unopened)
Utiliser la référence :
Veuillez lire le mode d'emploi avant la construction
Substrate: It should be solid, clean, dry (moisture content ≤ 10%), PH ≤ 10; for powdered substrates, use tools such as a spatula or wire brush to remove the powdered layer and completely remove mold spots.
Old paint film: Check the aging of the old paint film, and loose parts should be completely removed
Salting out: It is recommended to treat it with an oxalic acid solution of appropriate concentration (the specific concentration should be determined according to the degree of salting out, but the concentration generally does not exceed 5%), then rinse it with clean high-pressure water and dry it
Construction Method:
le revêtement au rouleau ou la pulvérisation
Dilution: Do not add water
Equipment cleaning: Wash with clean water promptly after construction. Safety. Labor protection: Safety measures should be taken during construction and labor protection clothing should be worn.
Spécifications de l'emballage :
Emballage de fûts de fer de 25 kg
Exigences environnementales :
*Stocké dans un entrepôt sec et ventilé à 5~35℃
*Environnement de construction : température ≥5℃ (température de base ≥10℃), humidité ≤85%.
*Transport : manipulé comme une marchandise non dangereuse, protégé contre le gel et l'exposition au soleil.