{"id":10626,"date":"2026-11-20T04:28:59","date_gmt":"2026-11-20T04:28:59","guid":{"rendered":"https:\/\/www.jinyupaint.com\/?p=10626"},"modified":"2026-11-20T04:29:01","modified_gmt":"2026-11-20T04:29:01","slug":"urethane-cement-data-sheet","status":"publish","type":"post","link":"https:\/\/www.jinyupaint.com\/es\/urethane-cement-data-sheet.html","title":{"rendered":"Urethane Cement Data Sheet: 12 Fields a Real TDS Shows"},"content":{"rendered":"<p class=\"wp-block-paragraph\">A urethane cement data sheet is a technical document, not a brochure, and a real one carries twelve fields that let a specifier check a product without asking the supplier anything.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A sheet that carries five fields can be used to place an order, not to compare products. The seven fields that decide a comparison are the ones usually missing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This article lists the twelve in the order they matter, explains what each one settles, and shows what the absence of a field tells you about the document you are holding.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-the-field-list-matters-more-than-the-headline\">Why the field list matters more than the headline<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A sheet with twelve fields produces a price that can be checked, and a sheet with five produces a price that has to be trusted. That is why the sheet is asked for before the price. The table below is the whole list, and the rest of this article walks down it.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Table 1: The twelve fields, in the order they matter.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th scope=\"col\">#<\/th><th scope=\"col\">Field<\/th><th scope=\"col\">Por qu\u00e9 es importante<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>1<\/td><td>Binder description<\/td><td>Tells you the chemistry, not the brand<\/td><\/tr>\n<tr><td>2<\/td><td>Components and mix ratio<\/td><td>Drives cost and consistency<\/td><\/tr>\n<tr><td>3<\/td><td>Aggregate and build range<\/td><td>Sets the duty the product suits<\/td><\/tr>\n<tr><td>4<\/td><td>Pot life at temperature<\/td><td>Decides crew size and batch size<\/td><\/tr>\n<tr><td>5<\/td><td>Temperatura de aplicaci\u00f3n<\/td><td>Decides whether the room can be worked<\/td><\/tr>\n<tr><td>6<\/td><td>Substrate moisture limit<\/td><td>Decides whether a barrier is needed<\/td><\/tr>\n<tr><td>7<\/td><td>Compressive and flexural strength<\/td><td>Load capacity at a stated age<\/td><\/tr>\n<tr><td>8<\/td><td>Abrasion resistance<\/td><td>Wear rate under traffic<\/td><\/tr>\n<tr><td>9<\/td><td>Adhesi\u00f3n<\/td><td>Bond to a prepared slab<\/td><\/tr>\n<tr><td>10<\/td><td>Chemical resistance table<\/td><td>Range at concentration and temperature<\/td><\/tr>\n<tr><td>11<\/td><td>Cure times<\/td><td>Walk-on, light duty, chemical<\/td><\/tr>\n<tr><td>12<\/td><td>Batch and declared performance<\/td><td>Traceability and legal basis<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">A headline figure such as compressive strength is easy to print and hard to use. It says nothing about thickness, mixing, cure or chemical range.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A urethane cement data sheet becomes useful at the point where every claim has a condition attached: a temperature, an age, a thickness or a test method.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Without those conditions, two sheets can show the same number for products that behave differently in a washdown room.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The test of a good document is simple. Can a contractor price from it, and can a client check the result at handover? If both answers are yes, the sheet is complete.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"fields-1-to-3-identity-components-and-mix\">Fields 1 to 3: identity, components and mix<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The first field is the binder description: a cementitious polyurethane hybrid, with the generic chemistry named rather than only the trade name. The <a href=\"https:\/\/www.jinyupaint.com\/es\/urethane-cement-definition.html\/\" target=\"_blank\" rel=\"noopener\">definition and chemistry<\/a> behind that phrase is what the rest of the sheet quantifies.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">That field also tells you whether the product is supplied as a kit with pre-weighed parts. A kit removes a class of site error and adds a class of logistics problem, which is worth knowing before the order.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The second is the component count and the mixing ratio, stated by weight and by volume, because the two do not agree for a three-component system. A sheet without that ratio cannot be priced accurately, since the powder-to-resin balance drives the cost per square meter more than anything else on the page.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The third is the aggregate grading and the build range the product is designed for. A sheet that lists one thickness for every duty is describing one product doing several jobs badly. A sheet that lists a range also answers a question buyers rarely ask, which is whether the product is built for a single duty or for several. A single-duty product is not inferior, but it should not be priced against a range.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The binder, the ratio and the grading answer what the material is, how it is made ready and where it belongs.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"fields-4-to-6-time-temperature-and-moisture\">Fields 4 to 6: time, temperature and moisture<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Field four is pot life at a stated temperature. A pot life quoted without a temperature is a number from a laboratory in spring. Pot life also varies with batch size, because a larger mix generates more heat and reacts faster, so a technical datasheet that quotes one figure is quoting the small-batch case.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Field five is the application temperature range for substrate and air, and the minimum cure temperature. Those are three numbers, not one.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Field six is the substrate moisture limit, with the test method used to establish it. This is the field that decides whether a barrier is needed, which makes it the one a plant manager should read first.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The two test methods are not interchangeable. A project that tests by one method cannot be compared with a limit stated in the other, and that mismatch is a common reason two surveys disagree. Where the limit is stated, it is usually a percentage by mass or a relative humidity figure, and it should say which.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A urethane cement data sheet that omits the moisture limit is leaving the biggest site risk to a conversation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"fields-7-to-9-strength-wear-and-adhesion\">Fields 7 to 9: strength, wear and adhesion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Field seven is compressive and flexural strength, with the test age and the specimen size. Strength at 28 days and strength at 7 days are different claims, and a urethane cement data sheet that reports strength without an age is reporting the best number the laboratory produced.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Field eight is abrasion resistance, with the method, the wheel and the load. A mass loss figure without conditions cannot be compared with anything.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Field nine is adhesion to the prepared substrate, with the test method and the failure mode expected. Two megapascals into the concrete is a pass; the same number at the interface is not. Adhesion is the field a floor fails on when everything else was correct, and a product with excellent strength and a poor bond lifts in sheets two years after a clean handover.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A compressive strength figure is checked on a cube in a laboratory, and a pull-off value is checked on the floor. Only the second describes the building you are standing in.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Strength, abrasion and adhesion are the only fields a client can re-test on site without a laboratory, which is where a technical datasheet earns its name.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"field-10-the-chemical-resistance-table\">Field 10: the chemical resistance table<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This is the field that decides whether a product is suitable, and the one most often reduced to a tick.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A useful table lists the chemical, the concentration, the temperature and the exposure time, with a rating that means something.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A tick against sulfuric acid without a concentration is worse than no entry, because it invites a specification that will fail.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Where a table gives ratings without a duration, the rating describes the shortest exposure the manufacturer tests rather than the longest spill the plant experiences. Ask for the tested duration, and treat a spill that stands for a week as a different test.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The table should also state what happened after exposure: mass change, hardness change, blistering or color shift.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A urethane cement data sheet that carries a real table is usually a sheet produced by a manufacturer who has run the tests rather than a distributor who has copied a summary.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"field-11-cure-times-in-three-stages\">Field 11: cure times in three stages<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Cure is not one number. The sheet should give walk-on time, light-duty time and full chemical resistance, each at a stated temperature. A document that gives one cure time is describing the most optimistic of the three and leaving the other two to be discovered.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Those figures are a field requirement rather than a schedule. How to plan a closure around them, including the reverse arithmetic from a delivery date, is set out in <a href=\"https:\/\/www.jinyupaint.com\/es\/urethane-cement-cure-time.html\/\" target=\"_blank\" rel=\"noopener\">cure schedule<\/a>, which covers the sequencing a data sheet should not attempt.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"field-12-traceability-and-legal-basis\">Field 12: traceability and legal basis<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A distributor sheet usually carries fewer fields than a manufacturer sheet, and that is not deceit. The distributor has the finished product and the manufacturer has the test data, and the two documents circulate separately.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The last field is the least read and the most useful in a dispute: the batch number, the standard the product is declared against, and the date of the document.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A technical datasheet with no revision date cannot be relied on, because products change and old sheets circulate for years.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A batch number on the delivery note and a batch number on the sheet should match. Where they do not, the floor that was tested is not necessarily the floor that was placed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Where a European project is involved, the declared performance document is the legal basis and the sheet is a summary of it. A United States project usually works from test reports against standard methods plus a manufacturer&#8217;s declaration, and the sheet then acts as the index to those reports.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The same discipline applies to a renovation where an existing floor is being matched. The old sheet, if it exists, tells you what the plant has been living with, and it is a better starting point than a new brochure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A document with those two items is one a client can put in a project file. Without them, a urethane cement data sheet is a brochure with numbers on it, however well it is printed.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"how-to-read-the-sheet-in-six-checks\">How to read the sheet in six checks<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The field order is the order of the file. The reading order is the order of the decision: the fields that can veto a project come first, the fields that set the price second, and the field that gets verified on site comes last.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The veto fields are the revision date, the component ratio and the moisture limit with its test method. A sheet that fails any of them cannot be used to compare anything, whatever its headline figure says.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The price fields are the chemical table and the cure times, which decide the system and the closure. The verification field is the build range, checked against <a href=\"https:\/\/www.jinyupaint.com\/es\/urethane-cement-thickness.html\/\" target=\"_blank\" rel=\"noopener\">thickness selection<\/a>, because a sheet that offers one thickness cannot serve four duties.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">That ordering is deliberate. Strength figures are the easiest to print and the least likely to decide a project, while moisture and chemistry decide most of them before a strength number is relevant. Keep a copy of the sheet you specified with the project file, not just the one supplied at handover, because when the two differ the one you specified describes the floor you asked for.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Three tiers follow from the same logic. A sheet missing the revision date or the batch route cannot go into a tender at all. A sheet missing the moisture limit or the chemical table can support a quotation but not a comparison. A sheet missing the component ratio leaves the price unchecked, because that ratio is what the cost per square meter is built from.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-to-ask-when-a-field-is-missing\">What to ask when a field is missing<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The five cases are set out as a table first, then explained one at a time.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Table 2: What a missing field does to the comparison, and what to request.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th scope=\"col\">Missing field<\/th><th scope=\"col\">Effect on the comparison<\/th><th scope=\"col\">What to request<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Mix ratio<\/td><td>Cost per square meter cannot be checked<\/td><td>The ratio by weight, on the sheet or in writing<\/td><\/tr>\n<tr><td>Moisture limit<\/td><td>Barrier risk stays unknown<\/td><td>The limit and the test method behind it<\/td><\/tr>\n<tr><td>Test age<\/td><td>Strength figures cannot be compared<\/td><td>The age and specimen size for each figure<\/td><\/tr>\n<tr><td>Chemical table<\/td><td>Chemical suitability is unverified<\/td><td>Tested agents, with concentration, temperature and duration<\/td><\/tr>\n<tr><td>Revision date<\/td><td>The sheet may describe an older product<\/td><td>The current version and its date<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Where a chemical resistance table is the missing item, ask which agents were tested and at what temperature. A supplier who has tested ten agents at two temperatures is telling you more than one who has tested forty at one.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ask in writing, and ask for the test report rather than a second summary.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Where no moisture limit can be produced, treat the product as unverified against a damp slab, and price the barrier risk into the comparison.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Where no chemical table at temperature can be produced, the chemical exposure is unverified, and the quotation should carry that as a stated risk rather than an assumption.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Where no mix ratio can be produced, the chain of responsibility between manufacturer and supplier is unclear, which matters at the first failure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The revision date, the ratio and the moisture limit take ten minutes to check, and they separate a technical document from a marketing one.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"putting-the-sheet-into-a-specification\">Putting the sheet into a specification<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Quote the fields, not the product, because the <a href=\"https:\/\/www.jinyupaint.com\/es\/urethane-cement-pu-concrete-pu-mortar.html\/\" target=\"_blank\" rel=\"noopener\">three markets<\/a> selling the material do not agree on the names. State the required moisture limit, the required chemical range and the required thickness.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Require the sheet with the revision date as part of the submittal, and require the declared performance document where the project needs one.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Require core samples for thickness and a pull-off test for adhesion, because those two fields are only claims until they are measured.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">That is also where a project file earns its keep. Two years later, the sheet with a revision date and the core results are the only evidence of what was specified and what was delivered.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A specification written from the field list is one that a contractor can price and a surveyor can check.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">That is the whole purpose of a urethane cement data sheet, and the reason twelve fields are better than two.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Table 3: Fields to require at submittal.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th scope=\"col\">Stage<\/th><th scope=\"col\">Require<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Tender<\/td><td>Binder, build range, chemical table<\/td><\/tr>\n<tr><td>Pre-start<\/td><td>Mix ratio, pot life, application temperature<\/td><\/tr>\n<tr><td>Pre-start<\/td><td>Moisture limit and slab reading<\/td><\/tr>\n<tr><td>Entrega<\/td><td>Core results, pull-off results<\/td><\/tr>\n<tr><td>Entrega<\/td><td>Revision date, batch, declared performance<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/www.jinyupaint.com\/wp-content\/uploads\/2026\/11\/urethane-cement-chemical-immersion-chips.jpg\" alt=\"Three coated sample chips standing in three glass jars of clear liquid on a bench, lit from behind so the liquid glows\" class=\"wp-image-10608\" srcset=\"https:\/\/www.jinyupaint.com\/wp-content\/uploads\/2026\/11\/urethane-cement-chemical-immersion-chips.jpg 800w, https:\/\/www.jinyupaint.com\/wp-content\/uploads\/2026\/11\/urethane-cement-chemical-immersion-chips-300x225.jpg 300w, https:\/\/www.jinyupaint.com\/wp-content\/uploads\/2026\/11\/urethane-cement-chemical-immersion-chips-768x576.jpg 768w, https:\/\/www.jinyupaint.com\/wp-content\/uploads\/2026\/11\/urethane-cement-chemical-immersion-chips-16x12.jpg 16w, https:\/\/www.jinyupaint.com\/wp-content\/uploads\/2026\/11\/urethane-cement-chemical-immersion-chips-600x450.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Figure 1: resistance is tested by immersion, not by a tick on a sheet.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"frequently-asked-questions\">Frequently asked questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"how-many-pages-should-a-urethane-cement-data-sheet-be\">How many pages should a urethane cement data sheet be?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Two to four. Length is not the test; the presence of the twelve fields is, and a two-page sheet can carry all of them.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"is-compressive-strength-the-most-important-field\">Is compressive strength the most important field?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. The moisture limit and the chemical table decide more projects, and thickness decides more service life.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"why-does-the-mix-ratio-matter-to-a-buyer\">Why does the mix ratio matter to a buyer?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Because it drives the cost per square meter and the consistency of the floor. A three-component system mixed by eye produces variable results.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-if-the-sheet-has-no-revision-date\">What if the sheet has no revision date?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Treat it as undated and ask for the current version. An undated sheet cannot be relied on in a dispute or in a submittal.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"do-ce-dop-or-astm-reports-replace-the-data-sheet\">Do CE, DoP or ASTM reports replace the data sheet?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. The declared performance or the test report is the legal document and the sheet is the working summary. A project usually needs both.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"can-i-compare-two-products-from-their-sheets-alone\">Can I compare two products from their sheets alone?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Only if both sheets carry the same fields with the same conditions. Otherwise you are comparing marketing copy.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-should-i-do-if-a-field-is-missing\">What should I do if a field is missing?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ask in writing for the test report. If it cannot be produced, treat the claim as unproven and price the risk accordingly.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"working-with-kaida-paint\">Working with Kaida Paint<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Kaida Paint issues a twelve-field urethane cement data sheet with a revision date, a chemical table at temperature and a stated moisture limit, and we will send the test reports behind it on request. Send the agents on your site and the room conditions, and we will mark which fields decide your specification.<\/p>","protected":false},"excerpt":{"rendered":"<p>A urethane cement data sheet is a technical document, not a brochure, and a real [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":10607,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"categories":[1],"tags":[2524,2526,2518,2525,2523],"class_list":["post-10626","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-faq","tag-cementitious-urethane-tds","tag-chemical-resistance-table","tag-declared-performance","tag-technical-datasheet-fields","tag-urethane-cement-data-sheet"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.2 (Yoast SEO v26.5) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Urethane Cement Data Sheet: 12 Fields a Real TDS Shows<\/title>\n<meta name=\"description\" content=\"Twelve fields every urethane cement data sheet must contain, from mix ratio to chemical resistance at temperature, and what a missing field tells you.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.jinyupaint.com\/es\/urethane-cement-data-sheet.html\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Urethane Cement Data Sheet: 12 Fields a Real TDS Shows\" \/>\n<meta property=\"og:description\" content=\"Twelve fields every urethane cement data sheet must contain, from mix ratio to chemical resistance at temperature, and what a missing field tells you.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.jinyupaint.com\/es\/urethane-cement-data-sheet.html\/\" \/>\n<meta property=\"og:site_name\" content=\"KAIDA PAINT\u00ae\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-20T04:28:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-20T04:29:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.jinyupaint.com\/wp-content\/uploads\/2026\/11\/urethane-cement-data-sheet-evidence-layout.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"jinyupaint\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"jinyupaint\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minuto\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.jinyupaint.com\/urethane-cement-data-sheet.html\",\"url\":\"https:\/\/www.jinyupaint.com\/urethane-cement-data-sheet.html\",\"name\":\"Urethane Cement Data Sheet: 12 Fields a Real TDS Shows\",\"isPartOf\":{\"@id\":\"https:\/\/www.jinyupaint.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.jinyupaint.com\/urethane-cement-data-sheet.html#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.jinyupaint.com\/urethane-cement-data-sheet.html#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.jinyupaint.com\/wp-content\/uploads\/2026\/11\/urethane-cement-data-sheet-evidence-layout.jpg\",\"datePublished\":\"2026-11-20T04:28:59+00:00\",\"dateModified\":\"2026-11-20T04:29:01+00:00\",\"author\":{\"@id\":\"https:\/\/www.jinyupaint.com\/#\/schema\/person\/c180feaa2102b492d985efe62f9cb01b\"},\"description\":\"Twelve fields every urethane cement data sheet must contain, from mix ratio to chemical resistance at temperature, and what a missing field tells you.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.jinyupaint.com\/urethane-cement-data-sheet.html#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.jinyupaint.com\/urethane-cement-data-sheet.html\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.jinyupaint.com\/urethane-cement-data-sheet.html#primaryimage\",\"url\":\"https:\/\/www.jinyupaint.com\/wp-content\/uploads\/2026\/11\/urethane-cement-data-sheet-evidence-layout.jpg\",\"contentUrl\":\"https:\/\/www.jinyupaint.com\/wp-content\/uploads\/2026\/11\/urethane-cement-data-sheet-evidence-layout.jpg\",\"width\":800,\"height\":600,\"caption\":\"A core, a cube specimen, a sample tin, a hand-held moisture meter and a thermometer laid in a row on a workbench, displays turned away\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.jinyupaint.com\/urethane-cement-data-sheet.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.jinyupaint.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Urethane Cement Data Sheet: 12 Fields a Real TDS Shows\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.jinyupaint.com\/#website\",\"url\":\"https:\/\/www.jinyupaint.com\/\",\"name\":\"KAIDA PAINT\u00ae\",\"description\":\"Industrial Coatings Manufacturer &amp; Global Flooring Solutions Contractor\",\"alternateName\":\"JINYU PAINT\u00ae\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.jinyupaint.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.jinyupaint.com\/#\/schema\/person\/c180feaa2102b492d985efe62f9cb01b\",\"name\":\"jinyupaint\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.jinyupaint.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/www.jinyupaint.com\/wp-content\/litespeed\/avatar\/b702e163685e9eae5ab604489f61127a.jpg?ver=1795151842\",\"contentUrl\":\"https:\/\/www.jinyupaint.com\/wp-content\/litespeed\/avatar\/b702e163685e9eae5ab604489f61127a.jpg?ver=1795151842\",\"caption\":\"jinyupaint\"},\"sameAs\":[\"https:\/\/www.jinyupaint.com\"],\"url\":\"https:\/\/www.jinyupaint.com\/es\/author\/jinyupaint\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Urethane Cement Data Sheet: 12 Fields a Real TDS Shows","description":"Twelve fields every urethane cement data sheet must contain, from mix ratio to chemical resistance at temperature, and what a missing field tells you.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.jinyupaint.com\/es\/urethane-cement-data-sheet.html\/","og_locale":"es_ES","og_type":"article","og_title":"Urethane Cement Data Sheet: 12 Fields a Real TDS Shows","og_description":"Twelve fields every urethane cement data sheet must contain, from mix ratio to chemical resistance at temperature, and what a missing field tells you.","og_url":"https:\/\/www.jinyupaint.com\/es\/urethane-cement-data-sheet.html\/","og_site_name":"KAIDA PAINT\u00ae","article_published_time":"2026-11-20T04:28:59+00:00","article_modified_time":"2026-11-20T04:29:01+00:00","og_image":[{"width":800,"height":600,"url":"https:\/\/www.jinyupaint.com\/wp-content\/uploads\/2026\/11\/urethane-cement-data-sheet-evidence-layout.jpg","type":"image\/jpeg"}],"author":"jinyupaint","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"jinyupaint","Tiempo de lectura":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.jinyupaint.com\/urethane-cement-data-sheet.html","url":"https:\/\/www.jinyupaint.com\/urethane-cement-data-sheet.html","name":"Urethane Cement Data Sheet: 12 Fields a Real TDS Shows","isPartOf":{"@id":"https:\/\/www.jinyupaint.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.jinyupaint.com\/urethane-cement-data-sheet.html#primaryimage"},"image":{"@id":"https:\/\/www.jinyupaint.com\/urethane-cement-data-sheet.html#primaryimage"},"thumbnailUrl":"https:\/\/www.jinyupaint.com\/wp-content\/uploads\/2026\/11\/urethane-cement-data-sheet-evidence-layout.jpg","datePublished":"2026-11-20T04:28:59+00:00","dateModified":"2026-11-20T04:29:01+00:00","author":{"@id":"https:\/\/www.jinyupaint.com\/#\/schema\/person\/c180feaa2102b492d985efe62f9cb01b"},"description":"Twelve fields every urethane cement data sheet must contain, from mix ratio to chemical resistance at temperature, and what a missing field tells you.","breadcrumb":{"@id":"https:\/\/www.jinyupaint.com\/urethane-cement-data-sheet.html#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.jinyupaint.com\/urethane-cement-data-sheet.html"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.jinyupaint.com\/urethane-cement-data-sheet.html#primaryimage","url":"https:\/\/www.jinyupaint.com\/wp-content\/uploads\/2026\/11\/urethane-cement-data-sheet-evidence-layout.jpg","contentUrl":"https:\/\/www.jinyupaint.com\/wp-content\/uploads\/2026\/11\/urethane-cement-data-sheet-evidence-layout.jpg","width":800,"height":600,"caption":"A core, a cube specimen, a sample tin, a hand-held moisture meter and a thermometer laid in a row on a workbench, displays turned away"},{"@type":"BreadcrumbList","@id":"https:\/\/www.jinyupaint.com\/urethane-cement-data-sheet.html#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.jinyupaint.com\/"},{"@type":"ListItem","position":2,"name":"Urethane Cement Data Sheet: 12 Fields a Real TDS Shows"}]},{"@type":"WebSite","@id":"https:\/\/www.jinyupaint.com\/#website","url":"https:\/\/www.jinyupaint.com\/","name":"KAIDA PAINT","description":"Fabricante de recubrimientos industriales y contratista de soluciones de pavimentos a nivel mundial","alternateName":"JINYU PAINT\u00ae","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.jinyupaint.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/www.jinyupaint.com\/#\/schema\/person\/c180feaa2102b492d985efe62f9cb01b","name":"jinyupaint","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.jinyupaint.com\/#\/schema\/person\/image\/","url":"https:\/\/www.jinyupaint.com\/wp-content\/litespeed\/avatar\/b702e163685e9eae5ab604489f61127a.jpg?ver=1795151842","contentUrl":"https:\/\/www.jinyupaint.com\/wp-content\/litespeed\/avatar\/b702e163685e9eae5ab604489f61127a.jpg?ver=1795151842","caption":"jinyupaint"},"sameAs":["https:\/\/www.jinyupaint.com"],"url":"https:\/\/www.jinyupaint.com\/es\/author\/jinyupaint"}]}},"_links":{"self":[{"href":"https:\/\/www.jinyupaint.com\/es\/wp-json\/wp\/v2\/posts\/10626","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jinyupaint.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jinyupaint.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jinyupaint.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jinyupaint.com\/es\/wp-json\/wp\/v2\/comments?post=10626"}],"version-history":[{"count":3,"href":"https:\/\/www.jinyupaint.com\/es\/wp-json\/wp\/v2\/posts\/10626\/revisions"}],"predecessor-version":[{"id":10659,"href":"https:\/\/www.jinyupaint.com\/es\/wp-json\/wp\/v2\/posts\/10626\/revisions\/10659"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jinyupaint.com\/es\/wp-json\/wp\/v2\/media\/10607"}],"wp:attachment":[{"href":"https:\/\/www.jinyupaint.com\/es\/wp-json\/wp\/v2\/media?parent=10626"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jinyupaint.com\/es\/wp-json\/wp\/v2\/categories?post=10626"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jinyupaint.com\/es\/wp-json\/wp\/v2\/tags?post=10626"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}